Ulvac Leak Detector - HELIOT900 Series
Category: Helium Mass Spectrometer Leak Detectors
Specifications
SKU
HELIOT901W1, HELIOT901D2, HELIOT904W2, HELIOT904D3 , HELIOT904D4 , Helium Leak Detector, Leak Detector, Sniffer, Leak Detection, NDT, Fine Leak Test, Hydrogen Leak Detector
Details
ULVAC HELIOT900 Series Leak Detector
Pls email sales@hexoind.com or contact us more the product and application detail.


HELIOT904W2
HELIOT904D3
HELIOT904D4
****
The HELIOT900 is our helium leak detector with; high speed pumping capability, user-friendly operation and guaranteed top performance in all kinds of leak testing situations.
Features
- High speed pumping capability:
5L/s pumping speed for helium IN ULTRA flow mode.
- Tablet type controller:
Wireless remote control is standard specification.
- Intuitive operation:
Simple with high-definition and eye-friendly test screen.
- Various backing pumps available:
Oil rotary vane and dry scroll pumps in different sizes.
- Mobile-friendly with maneuverable cart (HELIOT904_):
Low height type is also available (HELIOT901_).
- Ease of maintenance:
Tool-free removal maintenance panel, easy internal access for maintenance and maintenance instructions built in.
- Possible to detect hydrogen as well as helium gas by vacuum method.
Applications
- Piping assemblies and separate parts.
- Vacuum components and systems.
- Automotive parts, air conditioning, heat exchanger parts and assemblies.
- Packaging for food, pharmaceuticals, etc.
- Flow and permeation rate measurement of helium and hydrogen.
Specifications
|
Model
|
901W1 | 901D2 | 904W2 | 904D3 | 904D4 | ||
| Type | Base type | Mobile type | |||||
| Detectable gas | 4He, 2H2 | ||||||
|
Minimum detectable leak rate (4He)[Pa・m3/sec] |
<5E-13 | ||||||
|
Leak rate display range [Pa・m3/sec] |
4He | 0.01E-12~E-3 | |||||
| 2H2 | 0.01E-8~E-5 | ||||||
| Inlet pumping speed for(4He)[L/sec] | 5 | ||||||
| Max. connecting pressure[Pa] | <1200 Pa | ||||||
| Main pump Pumping peed[L/sec] | Turbo molecular pump:31 L/sec | ||||||
|
Fore pump: Pumping speed(50Hz/60Hz)[L/min] |
Oil rotary pump: 30/36 |
Dry scroll pump: 90/108 |
Oil rotary pump: 135/162 |
Dry scroll pump: 250/300 |
Dry scroll pump: 500/600 |
||
| Weight [kg] (including floor cart)) | Approx. 33(Approx. 46) | Approx. 37(Approx. 50) | Approx. 79 | Approx. 74 | Approx. 96 | ||
| Power consumption[VA] | 600 | 500 | 1100 | 650 | 1150 | ||
| Input power supply[V] | 100-120 or 200-240 | ||||||
| Inlet port flange | NW25(ISO) | ||||||
| Startup time[min] | <2 | ||||||
| External interface | RS232C, RS485, analog DC, digital I/O. | ||||||
| Language | English,Japanese,Korean,Simple Chinese,Traditional Chinese,German,Spanish,Russian | ||||||
| Controller unit | 7inch tablet type (wireless standard: IEEE 802.11 b/g/n) (*1) | ||||||
| Operation range | Wired | Cable length : 2m (standard), 5m (optional) | |||||
| Wireless | 40m(*2) | ||||||
| Battery lasting time[hr] | 3-5(*3) | ||||||
| Applicable standard | CE, IP30 | CE | |||||
*1 Applicable radio law. Tablet: Telec, CE, FCC. Main unit: Telec, CE, FCC, IC, C-TICK. “Wired operation spec” that doesn’t emit radio waves is also available (tablet controller has wireless radio on/off function).
*2 May change depending on operating environment.
*3 May change depending on communication condition, brightness, volume, etc.
[Sniffer Method]
|
Sniffer Method
|
AS9 | BS9 | BT9 |
| Detectable gas | 4He | ||
| Minimum leak rate display range[Pa・m3/sec] | 0.01E-8~E-5 | 0.01E-7~E-3 | |
| Flow rate[SLM] | <0.03 | Approx. 3 | |
| Sniffing inlet port | Handyprobe | Φ6mm tube fitting | |
| Tube[m] | 1-10 (*1) | ||
*1 Specified length per 1m.
Reasons for using our Helium Leak Detectors for Fine Leak Testing
Leak testing is crucial because, well, everything leaks! Here are the fundamental reasons for performing leak tests:
- Preventing Material Loss by Leakage Detecting and addressing leaks ensures that valuable materials are not lost due to escaping gases.
- Avoiding Contamination Leaks can introduce contaminants into a system, affecting product quality and reliability.
- Ensuring Product Performance and Reliability Leak-free products perform better and are more reliable, leading to satisfied customers.
- Reducing Liability Leaks can lead to safety hazards, environmental issues, and legal liabilities.
- Minimizing Production Output Loss System downtime caused by leaks can significantly impact production output.
Why Hexo Uses Helium as a Tracer Gas?
-
Helium’s Properties:
- Helium, with a molecular weight of 4 atomic mass units (amu), is readily available worldwide.
- Its low background noise makes it an excellent choice for leak detection applications.
- Helium is non-toxic, non-flammable, inert, and not easily absorbed.
- It allows for non-destructive testing (NDT).
- Variety of Helium Leak Detector Models: Hexo offers different models to suit your specific needs.
- Pump Options: Dry pumps or oil pumps are available for both cleanroom and non-cleanroom environments.
- Customizable Pumping Speed: Choose the pumping speed based on your process requirements.
- Flexible Types: Hexo provides options with or without carts, as well as handheld detectors.
- Suitable for Various Test Methods: Whether it’s spray vacuum or sniffing, Hexo detectors can handle different testing approaches.
- Comprehensive Support: Accessories, spare parts, and calibration services are available from Malaysia factory. Our experienced team provides technical support and training after sales.
- Rental Units: If needed, you can rent Hexo Helium Leak Detectors.
Hexo Helium Leak Detectors are available for sale in Malaysia, Indonesia, Philippines, Vietnam, Singapore, Thailand, and the South East Asia Region.
View more about Ulvac Leak Detector - HELIOT900 Series on main site